<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-07 18-52-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.00 MHz 5/5, 57 dBuV FREQ 3
Pilot RDS Phase Difference
6.7 kHz 3.5 kHz 3 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 72 kHz 17180 2,2061
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
7,0 dBr 8,04 dBr 8,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" FREQ 3 " F536 10 (Pop M) 1 0 1 3 18:52, 7.06.2024
RT
"Aerosmith -> I Don't Want To Miss A Thing "
AF EON
89.9, 99.0 MHz -
FM Scope Station: 99.00 MHz, signal: 5/5 (57 dBuV) Max at: 72 kHz MIN: 13 kHz % above 75 kHz: 2,2061 Acquired: 2024/06/07 18:51:19 Total samples: 17180 Equivalent time: 0:14:19 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 8,9 dBr MIN: 7,0 dBr AVE: 8,04 dBr % above 11,2 dBr: 0,0 Last value: 8,5 dBr (2024/06/07 18:51:18) Station: 99.00 MHz, signal: 5/5 (57 dBuV) 18:40 18:42 18:44 18:46 18:48 18:50 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality